RBH UNC100 two-door IP access controller

Installation and lifecycle support • NC & SC

New installation, existing-system service and ongoing support

For RBH UNC100 Controllers & Access Hardware, 360 Mobile Vision can supply the equipment, engineer the system, perform the installation, configure and test it, repair existing deployments, complete scheduled maintenance and remain available for technical support throughout North and South Carolina.

  • Product Supply
  • System Installation
  • Service & Repair
  • Maintenance & Upgrades
  • Technical Support

New installation: Need a complete project? We can take it from product selection through commissioning and handoff.

Existing system: Need help with installed equipment? We service, troubleshoot, maintain and expand existing systems.

Authorized · Certified · Carolinas

Authorized RBH dealer, certified installer and integrator

360 Mobile Vision sells, installs, programs and services RBH for businesses across North and South Carolina — AxiomXa, AxiomV and AxiomCLOUD, Integra32, UNC100 controllers and RBHView video. Being the authorized dealer as well as the installer is what gets you genuine equipment, a valid warranty and a manufacturer support path when something needs escalating.

  • DealerWe quote and supply genuine RBH equipment, licensing and subscriptions.
  • InstallerOur own technicians run the cable, mount the hardware, set the software up and test it — not a subcontractor you have never met.
  • IntegratorWe make it work with the cameras, doors, network and identity systems already in the building, rather than leaving you with two systems that do not talk.
  • Still here afterwardsService, repair, expansion and takeover of systems somebody else installed. Emergency cover round the clock.

Commercial security systems for the Carolinas

RBH UNC100 Controllers & Access Hardware

Controller and panel installation, IP and door programming, power, I/O, firmware planning, troubleshooting and maintenance.

RBH UNC100 two-door IP access controller
Certified RBH installerProduct supply & resaleProfessional installationSoftware setupService & maintenanceTechnical support

UNC100 and controller installation

The UNC100 is a native TCP/IP two-door controller used with RBH software families. RBH publishes onboard battery charging, encrypted communications, programmable RS-485 and a PoE IEEE 802.3at variant. Compatibility includes Integra32, AxiomV and AxiomXa when the controller and firmware match the approved platform.

We install the enclosure and power, terminate readers and door devices, configure IP communications and firmware, enroll the controller in software and test all normal, alarm and offline conditions.

RBH UNC100 two-door IP access controller
The RBH UNC100 provides network-connected control for two access-controlled openings.

RBH hardware families and field scope

UNC100

Two-door IP controller available in conventional-power and PoE kit arrangements. Reader, lock, input, output, battery and network budgets are checked against the current installation sheet.

UNC500 communications

Axiom enterprise systems can use UNC500 communications architecture. We verify the software edition, downstream controller topology, network design and support status before expansion.

IRC/URC/NIRC families

Existing RBH sites may contain several controller generations. We identify exact boards, firmware and topology before recommending reuse, firmware conversion or replacement.

IOC8 and I/O

Input/output modules add alarm monitoring and relay control. Every point is labeled in the panel and software and included in cause-and-effect testing.

Elevator control

Floor relay control requires a coordinated scope with the elevator and fire-alarm teams, plus an exact matrix of credential, schedule and emergency behavior.

Power and enclosures

Lock current, auxiliary loads, battery runtime, grounding, branch protection, wire gauge and environmental conditions are calculated—not inferred from the number of doors.

Controller service and maintenance

Health review

Inspect enclosure, supply and battery, board status, network errors, controller clocks, event upload, reader communications and recurring door alarms.

Corrective service

Isolate field wiring, reader, lock, input, power, network, firmware or software causes before replacing parts; then regression-test all affected openings.

Firmware planning

Use the RBH compatibility matrix for the exact management platform. Dealer-flashed or platform-specific firmware is handled only through approved channels with backup and rollback planning.

Closeout records

Update door schedules, IP and controller inventory, wiring labels, firmware, software release, battery date, test results and unresolved exceptions.

Official RBH hardware documentation

UNC100 product pageRBH hardware catalogInstallation guides and compatibility documents

Plan an installed and supported system

360 Mobile Vision can review the openings, existing equipment, network, software, credential workflow and integration requirements before recommending a current configuration for North Carolina and South Carolina.

Request a system consultation